1目的
To identify areas of the Code of Federal Regulations Title 30 (30CFR) Part 7, Subpart K, that requires clarification, in order to conduct consistent and appropriate flame testing.
识别领域的联邦法规法典标题30(30cfr)7部分,部分K,需要澄清,以便进行一致的和适当的火焰试验。
2.0 SCOPE
2适用范围
30 CFR Part 7, Subpart K.
7部分30cfr部分,K.
3.0 REFERENCES
参考文献3篇
Title 30, Code of Federal Regulations.
标题30,美国联邦法规法典。
4.0 DEFINITIONS
4定义
No items need defined.
项目不需要定义。
5.0 TEST EQUIPMENT
5试验设备
As listed in 30CFR Part 7.406.
7.406部分中列出的30cfr。
6.0 TEST SAMPLES
6个测试样品
Samples are described in 30CFR Parts 7.407 and 7.408, with the following modification. The test samples need not be humidity conditioned. A “Memorandum for the Record” dated July 18, 2005, and signed by Kenneth Sproul, Chief, Quality Assurance/Materials Testing Division, explains why humidity conditioning is not necessary. A copy of the memorandum is attached as “Appendix 1.”
样品在30cfr部分7.407和7.408,与随后的修改。试验样品不需要湿度条件。“备案”的备忘录的日期为2005年7月18日,由肯尼斯斯普劳尔,主任签字,质量保证/材料测试部门,解释了为什么湿度调节是不必要的。一份备忘录是作为“附录1”。
7.0 PROCEDURES
7个程序
As listed in 30CFR Parts 7.407 and 7.408.
列在30cfr部分7.407和7.408。
8.0 TEST DATA
8测试数据
Test data from the applicant will be maintained with the applicant’s approval file; test data from a product audit will be maintained with the audit file.
从申请人将测试数据的维护申请人的批准文件;从一个产品审核的测试数据将保持与审计文件。
9.0 PASS/FAIL CRITERIA
9通过或失败的判定标准
30CFR Parts 7.407 and 7.408 list the pass/fail criteria.
30cfr部分7.407和7.408列出通过/失败的标准。